Cabinet

1. First, we check the cabinet for damage or structural integrity
2. Each Corner Post is inspected for damage and deterioration

Cooling Pads

3. We make sure the pads are not damaged or deteriorated (those aged 5-7 years need replacing, because they lose their efficiency to hold water)
4. Then we check that the pads are correctly fitted and clips are intact.

Electrical Wiring

5. It’s time to look for damage and loose connections, including Earth Spade Connections.

Fan Motor

6. Your fan motor is tested to ensure it rotates freely and that the motor bearings are not worn. Confirm supply voltage is between 220V – 240V.
7. We check the motor speed sensor is clean, the beam sensors are vertically aligned, and that the sensor is correctly located in the motor’s end plate.
8. Your DC brake is inspected for correct operation (N-E1 control models only).

Fan

9. Your fan impeller is checked to ensure it’s centered within the bell housing.
10. We ensure the Collet is tight and not worn.
11. Your motor stator bracket and mountings are inspected for damage.
12. The fan impeller is checked for correct tension, blade height and angle.
13. Your belt tension and alignment is inspected (Breezair Centrifugal fans).
14. And we make sure the pulley wheel ratio isn’t causing the motor to exceed the maximum current draw (Breezair Centrifugal fans).

Fan Capacitor

15. We check that your Fan Capacitor is no more than 2 years old.

Printed Circuit Board

16. Printed Circuit Boards and Terminals are inspected for any visual damage (e.g., ants, diodes, resistors, burn marks).

Weather Seal Motor

17. Your weather seal motor operation checked for correct operation, engaging and opening/closing servo seal and opening/closing drain snorkel.
18. We make sure the Servo Seal louvres seal correctly in the closed position.
19. A check is done on the Auto Winter Seal to make sure it operates correctly to the open and closed positions.

Water

20. We check the Water Inlet Solenoid and water supply hose have filters fitted – and that they’re clean
21. The condition of your Water Inlet Valve ball float is inspected (if applicable)
22. We ensure the Water Inlet Valve opens in the normal operation sequence and closes at the correct water level. (If applicable)
23. And we check that your water pressure is sufficient to fill the tank within a 4-minute fill time if a Dump Valve is fitted (if applicable)

Water Pump

24. We check the water pump and distribution pipes to ensure they are intact and secured in place.
25. The pump operation is checked for noise and that the filter is clean
26. Your pump water discharge is inspected for correct pad saturation.

Drain Valve

27. Now we take a look at your Drain Snorkel, making sure it raises to the correct height above the High-Water Level Sensor.
28. Then we check that the Drain snorkel lowers to the correct position, allowing the tank to be completely drained
29. We check the Dump Valve inlet solenoid operation. (If applicable)
30. And we inspect the Dump Valve outlet valve operation. (If applicable)

Flexible Hose Connection

31. We’re looking for deterioration and blockages when we inspect your water supply line.
32. We inspect the Flexi Hose Connection
33. And we look at your Cooler Isolation Tap

Bleed-Rate Setting

34. Here, we check the Bleed discharge is correctly set for the model to maintain appropriate water quality and discharge concentration. You are advised if the bleed-rate settings are altered

Water Level Sensor

35. We test the Water Inlet Solenoid to make sure it closes at the contact of water at the High-Level Water Sensor and does not overflow out the Drain tube prior to the water being sensed at the High-Level

Float Valve

36. The condition of your Water Inlet Ball Valve washer is checked.
37. We check that the Water Inlet Valve opens in the normal operation sequence and closes at the correct water level

Water Drain

38. We make sure the drain discharge point is appropriate for the installation

Controller

39. We check that your wall controller is operating and in good working condition
40. We also make sure your wall controller is secured to the wall correctly

Air Delivery System

41. Your outlet diffusers are inspected for correct position and that the louvre blades are configured for best room air mixing.
42. We check that air distribution is sufficient from all outlets.
43. And we make sure there is adequate exhaust opening available for correct operation – Include Security Relief Grill

Rooftop Condition

44. Now we check around the work area for existing damaged tiles
Operation

Best Operating Practices

45. And finally, we discuss best practices for your operating system

Want to know more?
Talk to the Heating & Cooling experts

Are you ready to go? We can help!

plum-boys
Why people all over Melbourne choose Plum

Family Owned Business Since 1992

As a young plumber, Director Kyle Briggs founded Plum based on family values of honesty and trust.

Best Advice & Guidance

At Plum Trade Services, we pride ourselves on our award-winning accountability - with advice you can count on.

1,700+ 5-Star Google Reviews

It takes exceptional attention to detail and service to earn more than 1700 glowing customer reviews.

30 Years Local Business

From humble beginnings we have grown with our reputation for putting our customers first.

5x Wyndham Business Award Winners

Plum is a very proud, five-time winner of these prestigious awards - including Business of the Year.

Top Rated Customer Service

Our recognised high standard of professionalism and customer service is the envy of our peers.

Premium After-Sales Care

You enjoy life, while we take care of servicing, maintenance, and warranty repairs. No stress for you!

Fully Qualified, Honest & Reliable Tradesmen

We only hire trades who are respectful, trustworthy and reliable so you can be comfortable in your home.

No Contractors Used

All of our trades are full-time employees of Plum - and are accountable to us.

Easy to Deal With

Our happy, trustworthy staff pride themselves on setting the tone as soon as you make contact.

Very Responsive Communication

Our staff will never leave you hanging. They are highly responsive and engaging.

Warranty Agent for Brivis

As a warranty agent for Brivis, we can send out a technician to conduct repairs on their behalf.

Want to know more?
Talk to the Heating & Cooling experts